systemControlDevicesType

complexType · extension complexBaseType · all

Control device of an architecture or a connection

A control device makes a system architecture or a single connection switchable, e.g. a backup power supply that is only active after a failure. It defines two values of a control parameter, one for the active and one for the inactive state (systemStateType).

A static power breakdown case sets the state in the configuration of its specification (powerBreakdownSpecificationType). There, a <controlElement> of configuration/controlElements carries the @uID of the control device in <controlDeviceUID> and the value of the state in <controlParameter>: <controlParameterActive> switches the architecture or the connection on, <controlParameterInactive> switches it off.

Attributes

NameTypeConstraintsUseDefaultDescription
@externalDataDirectoryxsd:stringoptionalDirectory of the external file the element was read from, as URI
@externalDataNodePathxsd:stringoptionalPath of the parent element in the merged dataset, at which the element was inserted from an external file
@externalFileNamexsd:stringoptionalName of the external file the element was read from
@uIDxsd:IDrequiredUID

Child elements

NameTypeConstraintsOccurrenceHow often the element may appear at this place. The schema writes it as minOccurs and maxOccurs on the declaration.DefaultDescription
allThe children below may appear in any order. Each may appear at most once.
statesystemStateType[1..1] requiredValues of the control parameter for the active and the inactive state

Used by

In a dataset · 4 paths

In the schema · 2 declarations

TypeName
systemArchitectureTypecontrolDevices
systemConnectionTypecontrolDevices